Diagnostic
Poor idling
Cause: Closed air vent on fuel tank
Diagnostic
Cause: Closed air vent on fuel tank
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisSpec · 12 L
Procedure · 1. Put the control lever in the Neutral position and run the engine for 2–3 minutes at idling speed for cooling down if it has been running at full speed. 2. Turn the main switch key to the OFF position or push the st...
Spec · 10 cm (4 in.) conditions={"context":"Engine started in test tank"}
Procedure · 1. Do NOT trail the outboard motor in the tilted position; this may cause damage to the outboard motor, boat, etc. WARNING: Trailering in the tilted position may cause damage to the outboard motor, boat, etc. 2. Disco...
Diagnostic · Cause: Closed air vent on fuel tank