Specification
Verado Starting Battery: Minimum Marine Cranking Amps (MCA)
800 MCA conditions={"standard":"USA (SAE)"}
Specification
800 MCA conditions={"standard":"USA (SAE)"}
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisProcedure · 1. Set the lanyard stop switch to the "RUN" position. Refer to General Information – Lanyard Stop Switch. 2. Shift the outboard to the neutral (N) position. 3. For initial start of a new engine, or an engine that ran ...
Diagnostic · Cause: Incorrect starting procedure Test: Refer to Operation section
Spec · 800 minimum marine cranking amps (MCA), minimum reserve capacity 135 minutes RC25 MCA conditions={"standard":"USA (SAE)"}
Procedure · 1. Apply marine sealer to the shanks of the mounting bolts, not to the threads. WARNING: Clearance must be maintained between the vessel transom and the outboard transom bracket relief radius area. Failure to maintain...
Diagnostic · Cause: Weak battery or battery connections are loose or corroded