Specification
Function Switch / Fast Idle Mode: Fast Idle Mode – Activation Temperature Threshold
41 °F (5°C) conditions={"condition":"Outside ambient temperature below threshold after engine start"}
Specification
41 °F (5°C) conditions={"condition":"Outside ambient temperature below threshold after engine start"}
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisProcedure · 1. Turn the ignition switch key to the START position to crank the engine. WARNING: Do not operate the starter for more than 5 seconds at a time — this will overheat and damage the starter motor. Do NOT turn the key t...
Diagnostic · Cause: Engine not sufficiently warmed up before engine speed was raised Test: Check warm-up duration and fast idle lever usage prior to increasing RPM
Spec · Below 41 °F (5°C) conditions={"trigger":"Engine started, outside temperature below threshold"}
Procedure · 1. If ambient temperature is above 41°F (5°C), warm up the engine for 2 to 3 minutes before getting underway. 2. If ambient temperature is below 41°F (5°C), raise the fast idle lever to achieve approximately 2,000 rpm...
Diagnostic · Cause: Fast idle lever raised (side-mount type) Test: Check fast idle lever position