Diagnostic
No water flowing from cooling system indicator
Cause: Clogged discharge port or blocked water intake screens Test: Stop the engine, check the discharge port, then tilt the outboard motor and inspect the water intake screens for clogs
Diagnostic
Cause: Clogged discharge port or blocked water intake screens Test: Stop the engine, check the discharge port, then tilt the outboard motor and inspect the water intake screens for clogs
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisSpec · 10 minutes conditions={"water_type":"fresh water","method":"flush port connector"}
Procedure · 1. Idle the engine in neutral and check the cooling system indicator for water flow. 2. If water is flowing from the cooling system indicator, continue idling for 30 seconds. 3. Confirm the overheat indicator turns of...
Spec · Water cooling with thermostat
Procedure · 1. Use the power trim/tilt switch (see pages 75–76) to tilt the outboard motor up so the propeller and gear case clear the bottom. 2. Proceed at low speed. 3. Monitor water flow from the cooling system indicator (see ...
Diagnostic · Cause: Cooling system problem such as clogged water intakes Test: Inspect water intakes for blockage