Diagnostic
Unwanted motion of ERC control handle
Cause: Insufficient handle or detent tension Test: Check handle and detent tension by attempting to move handle; if too easy to move, tension is too low.
Diagnostic
Cause: Insufficient handle or detent tension Test: Check handle and detent tension by attempting to move handle; if too easy to move, tension is too low.
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisSpec · Clockwise conditions={"action":"Increase tension"}
Procedure · 1. Locate the control handle tension adjustment screw on the ERC remote control handle. 2. Turn the screw clockwise to increase tension (prevents unwanted motion in rough water). 3. Turn the screw counterclockwise to ...
Spec · Counterclockwise conditions={"action":"Decrease tension"}
Procedure · 1. Locate the detent tension adjustment screw on the ERC remote control handle. 2. Turn the screw clockwise to increase tension (increase effort to move handle out of detent positions). 3. Turn the screw counterclockw...
Diagnostic · Cause: Failure causing forced neutral/idle on port outer engine; inner port engine also forced to neutral/idle Test: Move port control handle back to neutral then into gear to restore inner engine operation