Diagnostic
Power tilt switch inoperative
Cause: Battery is dead Test: Check battery charge; if dead, use the manual relief valve to allow manual tilting
Diagnostic
Cause: Battery is dead Test: Check battery charge; if dead, use the manual relief valve to allow manual tilting
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisSpec · 2 N·m (ft·lb: 1.5, kgf·m: 0.2)
Procedure · 1. Open the manual relief valve completely in the Manual direction to allow the outboard motor to be tilted manually. WARNING: Ensure the manual relief valve is fully closed again before operating the outboard motor. ...
Spec · 2 N·m conditions={"imperial":"1.5 ft·lb","metric_kgf":"0.2 kgf·m"}
Procedure · 1. Ensure nobody is under the outboard motor before opening the manual relief valve, especially if the motor is in the tilted-up position. WARNING: If the outboard motor is in the tilted-up position, it will tilt down...
Diagnostic · Cause: Dead battery or failed power tilt switch. Test: Attempt to operate the power tilt switch; if no response, check battery charge and switch continuity.