Specification
MFS 6BZ: Starting System (EF/EP)
Electric starter motor conditions={"variant":"EF/EP","note":"With Manual Start"}
Specification
Electric starter motor conditions={"variant":"EF/EP","note":"With Manual Start"}
Open chat with this engine and topic preloaded so you can troubleshoot faster.
Ask Boat Guru about thisProcedure · 1. Fuel System – Check the amount of fuel in the tank. Replenish as needed. WARNING: Do not use outboard motor if any abnormality is found during pre-operation check or it could result in severe damage to the motor or...
Diagnostic · Cause: Short-circuit or electrical overload in the system Test: Remove fuse and visually inspect for blown condition; replace with fuse of identical specified rating only.
Spec · Electric starter motor (with manual start)
Procedure · 1. Place the shift lever in the neutral position and start the engine and run at idle speed for 3–5 minutes. 2. Check if a steady stream of water flows from the cooling water check port. 3. Stop the engine and turn of...
Diagnostic · Cause: Underlying electrical fault not corrected prior to fuse replacement Test: Attempt to identify and correct the root cause of the blown fuse before replacing; if fuse continues to blow, request an authorized Toha...